Three Phase Hybrid Storage Inverter 3-12 kW
The Afore AF Series three phase storage inverters are designed to increase energy independence for homeowners and commercial users.
The power range is from 3.0kW to 30kW, compatible with high voltage (150-800V) batteries.
Energy management is based on time-of-use and demand charge rate structures, significantly reduce the amount of energy purchased from public grid.
Thanks for the UPS function (switch time < 10ms), enables the crucial loads power on during outages. Additionally, under the backup operation mode, the inverter provides you up to 150% peak output overloading.
Add to wishlist
Share
PV Input | AF3K-THP | AF4K-THP | AF5K-THP | AF6K-THP |
Max. DC Input Power (kW) | 5 | 6 | 7.5 | 9 |
Max. PV Voltage (V) | 1000 | |||
Rated DC Input Voltage (V) | 620 | |||
DC Input Voltage Range (V) | 150 – 1000 | |||
MPPT Voltage Range (V) | 150 – 850 | |||
Full MPPT Range(V) | 200 – 850 | 250 – 850 | ||
Start-up Voltage (V) | 160 | |||
Max. DC Input Current (A) | 20 x 2 | |||
Max. Short Current(A) | 30 x 2 | |||
No. of MPPT Tracker / Strings | 2/2 | |||
Battery Port | ||||
Battery Nominal Voltage (V) | 100 | 100 | 100 | 150 |
Battery Voltage Range (V) | 80 – 600 | |||
Max. Charge/Discharge Current (A) | 50 | |||
Max. Charge/Discharge Power (W) | 3K | 4K | 5K | 6K |
Charging Curve | 3 Stages | |||
Compatible Battery Type | Li-ion battery | |||
AC Grid Output | AF3K-THP | AF4K-THP | AF5K-THP | AF6K-THP |
Nominal AC Output Power (VA) | 3000 | 4000 | 5000 | 6000 |
Max. AC Input Power | 4500 | 6000 | 7500 | 9000 |
Max. AC Output Current (A) | 5.3 | 7 | 8.5 | 10.5 |
Nominal AC Voltage (V) | 230 / 400 | |||
Nominal AC Frenquency (Hz) | 50 / 60 | |||
Power Factor | 1(- 0.8 – 0.8) | |||
Current THD (%) | < 3 % | |||
AC Load Output (Back-up) | ||||
Nominal Output Power (VA) | 3000 | 4000 | 5000 | 6000 |
Nominal Output Voltage (V) | 230 / 400 | |||
Nominal Output Frequency (Hz) | 50 / 60 | |||
Nominal Output Current (A) | 4.4 | 5.8 | 7.3 | 8.7 |
Peak Output Power | 3300VA, 60s | 4400VA, 60s | 5500VA, 60s | 6600VA, 60s |
THDV (with linear load) | < 3 % | |||
Switching Time (ms) | < 10 | |||
Efficiency | AF3K-THP | AF4K-THP | AF5K-THP | AF6K-THP |
Europe Efficiency | 97.50 % | |||
Max. Efficiency | 98.00 % | |||
Battery Charge/Discharge Efficiency | 98.00 % | |||
Protection | ||||
Reverse Polarity Protection | Yes | |||
Over Current / Voltage Protection | Yes | |||
Anti-islanding Protection | Yes | |||
AC Short-ciruit Protection | Yes | |||
Leakage Current Detection | Yes | |||
Ground Fault Monitoring | Yes | |||
Grid Monitoring | Yes | |||
Enclosure Protect Level | IP65 | |||
General Data | AF3K-THP | AF4K-THP | AF5K-THP | AF6K-THP |
Dimensions (W x H x D, mm) | 558 x 535 x 260 mm | |||
Weight (kg) | 29kg | |||
Topology | Transformerless | |||
Cooling Concept | Intelligent Fan | |||
Relatively Humidity | 0 – 100 % | |||
Operating Temperature Range (°C) | – 25 to 60 °C | |||
Operating Altitude (m) | < 4000 | |||
Noise Emission (dB) | < 30 | |||
Standby Consumption (W) | < 5 | |||
Display & Communication Interfaces | LCD, LED, RS485, CAN, Wi-Fi, GPRS, 4G | |||
Certification & Approvals | NRS097, G98/G99, EN50549-1, C10/C11, AS4777.2, VDE-AR-N4105, VDE0126, IEC62109-1, IEC62109-2 | |||
EMC | EN61000-6-2, EN61000-6-3 |
PV Input | AF8K-THP | AF10K-THP | AF12K-THP |
Max. DC Input Power (kW) | 12 | 15 | 18 |
Max. PV Voltage (V) | 1000 | ||
Rated DC Input Voltage (V) | 620 | ||
DC Input Voltage Range (V) | 150 – 1000 | ||
MPPT Voltage Range (V) | 150 – 850 | ||
Full MPPT Range(V) | 300 – 850 | 500 – 850 | |
Start-up Voltage (V) | 160 | ||
Max. DC Input Current (A) | 20 x 2 | ||
Max. Short Current(A) | 30 x 2 | ||
No. of MPPT Tracker / Strings | 2/2 | ||
Battery Port | |||
Battery Nominal Voltage (V) | 200 | 250 | 300 |
Battery Voltage Range (V) | 80 – 600 | 120 – 650 | |
Max. Charge/Discharge Current (A) | 50 | ||
Max. Charge/Discharge Power (W) | 8K | 10K | 12K |
Charging Curve | 3 Stages | ||
Compatible Battery Type | Li-ion battery | ||
AC Grid Output | AF8K-THP | AF10K-THP | AF12K-THP |
Nominal AC Output Power (VA) | 8000 | 10000 | 12000 |
Max. AC Input Power | 12000 | 15000 | 18000 |
Max. AC Output Current (A) | 13.5 | 17 | 21.5 |
Nominal AC Voltage (V) | 230 / 400 | ||
Nominal AC Frenquency (Hz) | 50 / 60 | ||
Power Factor | 1(- 0.8 – 0.8) | ||
Current THD (%) | < 3 % | ||
AC Load Output (Back-up) | |||
Nominal Output Power (VA) | 8000 | 10000 | 12000 |
Nominal Output Voltage (V) | 230 / 400 | ||
Nominal Output Frequency (Hz) | 50 / 60 | ||
Nominal Output Current (A) | 11.6 | 14.5 | 17.4 |
Peak Output Power | 8800VA, 60s | 11000VA, 60s | 13200VA, 60s |
THDV (with linear load) | < 3 % | ||
Switching Time (ms) | < 10 | ||
Efficiency | AF8K-THP | AF10K-THP | AF12K-THP |
Europe Efficiency | 97.50 % | ||
Max. Efficiency | 98.20 % | 98.30 % | |
Battery Charge/Discharge Efficiency | 98.00 % | ||
Protection | |||
Reverse Polarity Protection | Yes | ||
Over Current / Voltage Protection | Yes | ||
Anti-islanding Protection | Yes | ||
AC Short-ciruit Protection | Yes | ||
Leakage Current Detection | Yes | ||
Ground Fault Monitoring | Yes | ||
Grid Monitoring | Yes | ||
Enclosure Protect Level | IP65 | ||
General Data | AF8K-THP | AF10K-THP | AF12K-THP |
Dimensions (W x H x D, mm) | 558 x 535 x 260 mm | ||
Weight (kg) | 29kg | ||
Topology | Transformerless | ||
Cooling Concept | Intelligent Fan | ||
Relatively Humidity | 0 – 100 % | ||
Operating Temperature Range (°C) | – 25 to 60 °C | ||
Operating Altitude (m) | < 4000 | ||
Noise Emission (dB) | < 30 | ||
Standby Consumption (W) | < 5 | ||
Display & Communication Interfaces | LCD, LED, RS485, CAN, Wi-Fi, GPRS, 4G | ||
Certification & Approvals | NRS097, G98/G99, EN50549-1, C10/C11, AS4777.2, VDE-AR-N4105, VDE0126, IEC62109-1, IEC62109-2 | ||
EMC | EN61000-6-2, EN61000-6-3 |
Be the first to review “Three Phase Hybrid Storage Inverter 3-12 kW” Cancel reply