Three Phase Hybrid Storage Inverter 3-30 kW

The Afore AF Series three phase storage inverters are designed to increase energy independence for homeowners and commercial users.
The power range is from 3.0kW to 30kW, compatible with high voltage (150-800V) batteries.
Energy management is based on time-of-use and demand charge rate structures, significantly reduce the amount of energy purchased from public grid.
Thanks for the UPS function (switch time < 10ms), enables the crucial loads power on during outages. Additionally, under the backup operation mode, the inverter provides you up to 150% peak output overloading.

Add to wishlist
Share
    PV Input AF3K-TH AF4K-TH AF5K-TH AF6K-TH AF8K-TH AF10K-TH
    Max. DC Input Power (kW) 5 6 7.5 9 12 15
    Max. PV Voltage (V) 1000
    Rated DC Input Voltage (V) 620
    DC Input Voltage Range (V) 150 – 1000
    MPPT Voltage Range (V) 150 – 850
    Full MPPT Range(V) 200 – 850 250 – 850 300 – 850 500 – 850
    Start-up Voltage (V) 160
    Max. DC Input Current (A) 20 x 2
    Max. Short Current(A) 30 x 2
    No. of MPPT Tracker / Strings 2/2
    Battery Port
    Battery Nominal Voltage (V) 200 200 200 250 300 400
    Battery Voltage Range (V) 150 – 800
    Max. Charge/Discharge Current (A) 30
    Max. Charge/Discharge Power (kW) 3 4 5 6 8 10
    Charging Curve 3 Stages
    Compatible Battery Type Li-ion battery
    AC Grid AF3K-TH AF4K-TH AF5K-TH AF6K-TH AF8K-TH AF10K-TH
    Nominal AC Output Power (kW) 3 4 5 6 8 10
    Max. AC Input/Output Power (kVA) 4.5 / 3.3 6 / 4.4 7.5 / 5.5 9 / 6.6 12 / 8.8 15 / 11
    Max. AC Output Current (A) 5.3 7 8.5 10.5 13.5 17
    Nominal AC Voltage (V) 230 / 400
    Nominal AC Frenquency (Hz) 50 / 60
    Power Factor 1(- 0.8 – 0.8)adjustable
    Current THD (%) < 3 %
    AC Load Output (Back-up)
    Nominal Output Power (VA) 3000 4000 5000 6000 8000 10000
    Nominal Output Voltage (V) 230 / 400
    Nominal Output Frequency (Hz) 50 / 60
    Nominal Output Current (A) 4.4 5.8 7.3 8.7 11.6 14.5
    Peak Output Power 3300VA, 60s 4400VA, 60s 5500VA, 60s 6600VA, 60s 8800VA, 60s 11000VA, 60s
    THDV (with linear load) < 3 %
    Switching Time (ms) < 10
    Efficiency AF3K-TH AF4K-TH AF5K-TH AF6K-TH AF8K-TH AF10K-TH
    Europe Efficiency 97.50 %
    Max. Efficiency 98.00 % 98.20 %
    Battery Charge/Discharge Efficiency 98.00 %
    Protection
    Reverse Polarity Protection Yes
    Over Current / Voltage Protection Yes
    Anti-islanding Protection Yes
    AC Short-ciruit Protection Yes
    Leakage Current Detection Yes
    Ground Fault Monitoring Yes
    Grid Monitoring Yes
    Enclosure Protect Level IP65
    General Data AF3K-TH AF4K-TH AF5K-TH AF6K-TH AF8K-TH AF10K-TH
    Dimensions (W x H x D, mm) 370 x 497 x 192 mm
    Weight (kg) 20.8kg
    Topology Transformerless
    Cooling Concept Natural Convection Intelligent Fan
    Relatively Humidity 0 – 100 %
    Operating Temperature Range (°C) – 25 to 60 °C
    Operating Altitude (m) < 4000
    Noise Emission (dB) < 30
    Standby Consumption (W) < 5
    Display & Communication Interfaces LCD, LED, RS485, CAN, Wi-Fi, GPRS, 4G
    Certification & Approvals NRS097, G98/G99, EN50549-1, C10/C11, AS4777.2, VDE-AR-N4105, VDE0126,  IEC62109-1, IEC62109-2
    EMC EN61000-6-2, EN61000-6-3
    PV Input AF12K-TH AF15K-TH AF17K-TH AF20K-TH AF25K-TH AF30K-TH
    Max. DC Input Power (kW) 18 22.5 25.5 30 37.5 45
    Max. PV Voltage (V) 1000
    Rated DC Input Voltage (V) 620
    DC Input Voltage Range (V) 150 – 1000
    MPPT Voltage Range (V) 150 – 850
    Full MPPT Range(V) 500 – 850
    Start-up Voltage (V) 160
    Max. DC Input Current (A) 20 x 2 20 + 32 32 x 2 40 x 2
    Max. Short Current(A) 30 x 2 30 + 48 48 x 2 60 x 2
    No. of MPPT Tracker / Strings 2/2 2/3 2/4 2/4
    Battery Port
    Battery Nominal Voltage (V) 450 500 400 500 500 550
    Battery Voltage Range (V) 150 – 800
    Max. Charge/Discharge Current (A) 30 50 50 50 60 60
    Max. Charge/Discharge Power (kW) 12 15 17 20 25 30
    Charging Curve 3 Stages
    Compatible Battery Type Li-ion battery
    AC Grid AF12K-TH AF15K-TH AF17K-TH AF20K-TH AF25K-TH AF30K-TH
    Nominal AC Output Power (kW) 12 15 17 20 25 30
    Max. AC Input/Output Power (kVA) 18 / 13.2 22.5 / 16.5 25.5 / 18.7 30 / 22 37.5 / 27.5 45 / 33
    Max. AC Output Current (A) 21.5 27 30 32 40 48
    Nominal AC Voltage (V) 230 / 400
    Nominal AC Frenquency (Hz) 50 / 60
    Power Factor 1(- 0.8 – 0.8)adjustable
    Current THD (%) < 3 %
    AC Load Output (Back-up)
    Nominal Output Power (VA) 12000 15000 17000 20000 25000 30000
    Nominal Output Voltage (V) 230 / 400
    Nominal Output Frequency (Hz) 50 / 60
    Nominal Output Current (A) 17.4 21.8 24.7 29 36.3 43.5
    Peak Output Power 13200VA, 60s 16500VA, 60s 18700VA, 60s 22000VA, 60s 27500VA, 60s 33000VA, 60s
    THDV (with linear load) < 3 %
    Switching Time (ms) < 10
    Efficiency AF12K-TH AF15K-TH AF17K-TH AF20K-TH AF25K-TH AF30K-TH
    Europe Efficiency 97.50 % 97.80 % 98.00 % 98.10 %
    Max. Efficiency 98.30 % 98.50 %
    Battery Charge/Discharge Efficiency 98.00 %
    Protection
    Reverse Polarity Protection Yes
    Over Current / Voltage Protection Yes
    Anti-islanding Protection Yes
    AC Short-ciruit Protection Yes
    Leakage Current Detection Yes
    Ground Fault Monitoring Yes
    Grid Monitoring Yes
    Enclosure Protect Level IP65
    General Data AF12K-TH AF15K-TH AF17K-TH AF20K-TH AF25K-TH AF30K-TH
    Dimensions (W x H x D, mm) 370 x 497 x 192 mm 558 x 535 x 260 mm
    Weight (kg) 20.8kg 29kg 36kg
    Topology Transformerless
    Cooling Concept Intelligent Fan
    Relatively Humidity 0 – 100 %
    Operating Temperature Range (°C) – 25 to 60 °C
    Operating Altitude (m) < 4000
    Noise Emission (dB) < 30 < 40
    Standby Consumption (W) < 5
    Display & Communication Interfaces LCD, LED, RS485, CAN, Wi-Fi, GPRS, 4G
    Certification & Approvals NRS097, G98/G99, EN50549-1, C10/C11, AS4777.2, VDE-AR-N4105, VDE0126,  IEC62109-1, IEC62109-2
    EMC EN61000-6-2, EN61000-6-3

    Reviews

    There are no reviews yet.

    Be the first to review “Three Phase Hybrid Storage Inverter 3-30 kW”

    Your email address will not be published. Required fields are marked *