Three Phase PV String Inverter 70-110 kW

The Afore BNT Series Three-phase string inverters are designed for residential and small commercial PV system applications, rating from 3kW to 25kW. All models have unibody housings with aluminum structure which is anodized, increasing durability and effectively prevents corrosion.
Equipped with external inductors, the unibody housings can ensure efficient heat dissipation, which significantly improves the reliability and extends the life of the inverters.
Communication implements are via the Wi-Fi module (can be changed to Ethernet / GPRS). Check the system status anytime and anywhere via
online portal or APP.

Add to wishlist
Share
    PV Input Data BNT070KTL BNT075KTL BNT080KTL BNT090KTL BNT100KTL BNT110KTL
    Max. DC Power ( W ) 105000 112500 120000 135000 150000 165000
    Max. DC Voltage ( V ) 1100
    MPPT Voltage Range ( V ) 200 – 1000
    MPPT Full Power Voltage Range ( V ) 500 – 850
    Rated Input Voltage ( V ) 620
    Start-up Voltage ( V ) 200
    Max. Input Current ( A ) 38 x 6
    Max. Short Current ( A ) 48 x 6
    No. of MPP Tracker / No. of PV String 6/12
    Input Connector Type MC4
    AC Output Data BNT070KTL BNT075KTL BNT080KTL BNT090KTL BNT100KTL BNT110KTL
    Max. Output Power ( VA ) 77000 82500 88000 99000 110000 110000
    Nominal Output Power ( W ) 70000 75000 80000 90000 100000 110000
    Max. Output Current ( A ) 111 120 127 143 158 158
    Nominal Output Voltage ( V ) 3P+N+PE /3P+PE 230/400
    Grid Voltage Range 260Vac-519Vac (according to local standard)
    Nominal Output Frequency ( Hz ) 50/60
    Grid Frequency Range 45-55Hz/55-66Hz(according to local standard)
    Output Power Factor 1 default (adjustable from 0.8 leading to 0.8 lagging)
    Output Current THD <3%
    Efficiency BNT070KTL BNT075KTL BNT080KTL BNT090KTL BNT100KTL BNT110KTL
    Max. Efficiency 99.00%
    Euro Efficiency 98.30% 98.40%
    Protection BNT070KTL BNT075KTL BNT080KTL BNT090KTL BNT100KTL BNT110KTL
    PV Reverse Polarity Protection YES
    PV Insulation Resistance Detection YES
    AC Short Circuit Protection YES
    AC Over Current Protection YES
    AC Over Voltage Protection YES
    Anti-Islanding Protection YES
    Residual Current Detection YES
    Over Temperature Protection YES
    Integrated DC switch YES
    Surge Protection Integrated (Type II)
    Smart IV Curve Scaning YES
    Quick Arc Fault Circuit Interruption Optional
    General Data BNT070KTL BNT075KTL BNT080KTL BNT090KTL BNT100KTL BNT110KTL
    Dimensions (W x H x D, mm) 979 x 610 x 310
    Weight ( kg ) 72 76
    Protection Degree IP65
    Enclosure Material Aluminum
    Ambient Temperature Range (°C ) -25 to 60
    Humidity Range 0 -100%
    Topology Transformerless
    Communication Interface RS485 / WiFi / Wire Ethernet / GPRS (optional)
    Cooling Concept Intelligent fan cooling
    Noise Emission ( db ) <55 <60
    Night Power Consumption ( W ) <1
    Max. Operation Altitude ( m ) ≤4000
    Certifications and Standards BNT070KTL BNT075KTL BNT080KTL BNT090KTL BNT100KTL BNT110KTL
    EMC Standard EN/IEC 61000-6-2, EN/IEC 61000-6-3, EN61000-3-2, EN61000-3-3, EN61000-3-11, EN61000-3-12
    Safety Standard IEC 60068, UL1741, EN62109
    Grid-connection IEEE1547, CSA C22, EN50549, VDE4105, VDE0126, RD1699,

    ABNT NBR16149 & 16150, AS4777.2, NB/T32004, G98/G99, IEC61727